Safety and compliance: Command Centre usually protects a business, so treat any integration as a change to a production security system. Get the site owner's and integrator's agreement before connecting anything, test somewhere safe where you can, and make sure doors and alarms still work with the integration switched off.
The official documentation
Gallagher publishes developer documentation at gallaghersecurity.github.io, including the Command Centre REST API reference (version 1.0.0, with change notes up to 9.70 at the time of writing). It is split across several pages, including alarms and events and cardholders. Start from the index page for the rest.
For setting up the Command Centre server to answer REST calls, the docs point you to the Configuration Client online help: search the Configuration Client's online help for "REST". Gallagher also has a Command Centre Cloud API Gateway page for cloud access, and a knowledge hub article on the REST API.
Licences matter
The reference pages say, for example, that calls return 403 Forbidden if the site lacks the relevant licence (the docs mention RESTEvents and RESTCardholders). The community integration below says it needs the RESTStatus and RESTOverrides features. Ask your integrator what the site's licence includes before you plan anything.
How authentication works
Per the docs, clients put a pre-shared API key in the Authorization header, using the method GGL-API-KEY (or HTTP Basic style in version 9.0 and later). The key is generated when you create an endpoint for your clients in Command Centre. Depending on the site configuration, the API may also require a pinned client TLS certificate with each request. Treat the API key like a password, and do not paste real ones into forum posts.
The community Home Assistant integration
devnull-nz/Home-Assistant-Gallagher-Integration is a custom component installed via HACS. Per its README it can monitor and open doors, monitor and override alarm zones (user modes 1 and 2 are not supported) and access zones (Free and Secure without PIN only) and outputs, monitor inputs, and monitor fence zone voltage. Its README lists a known issue: if the Command Centre server is offline for an extended period the update subscription may not reconnect.
Planning checklist
- Written agreement from the site owner and your integrator.
- A dedicated REST client, operator and operator group with the minimum privileges, and IP filtering to the Home Assistant host (the README describes this).
- A DHCP reservation, a security VLAN, no port-forwarding. Use a VPN for remote access.
- Decide whether you need control (open a door, override a zone) or monitoring only. Monitoring only is much safer.
- A plan for rotating the key when staff change.