Safety and compliance: a security and access controller must keep working on its own. If the site is monitored, tell the monitoring company before changing anything. In Australia, intruder alarm installation and maintenance is covered by AS/NZS 2201.1, and licensing varies by state. Have your installer do the programming and the service setup.
The routes ICT documents
- Automation and Control service: a service you enable on the controller that listens on a TCP port and lets another system monitor and control doors, areas, inputs, outputs and variables. An ICT application note describes the settings (service type, start mode, TCP port, checksum type, status requests, acknowledgements). Note the encryption setting, covered below.
- Protege WX web interface and API: the WX controller has a built-in HTTPS web interface and a DLL-based API. The WX DLL API reference covers authentication and commands.
- Protege GX: ICT's custom integration tools page describes options for GX such as SOAP, MSMQ, Modbus and event reporting.
- Home Assistant (community): ICT Protege Automation is a custom integration that connects to the controller's Automation service. Per its README it provides door lock and unlock with open and closed state, areas (arm away, disarm, alarm active), inputs with automatic trouble sensors and bypass, and outputs.
The README says to match these on the controller's Automation service: encryption level None, checksum type 8-bit sum, "Numbers are Big Endian" unchecked, "Allow Status Requests When Not Logged In" and "Ack Commands" ticked, and "Expect Ack For Status Monitoring" unticked to avoid connection drops. It uses port 21000. An ICT application note I found mentions a different default port, so treat the port as whatever you configure on the service and make the integration match it.
Plan for the security trade-off
With encryption set to None, commands and your service PIN cross the network in clear form. That is workable on a tightly controlled network, but it is a reason to be strict:
- Put the controller on a security VLAN. Allow only the Home Assistant host to reach the Automation service port.
- Never port-forward it. For remote access use a VPN.
- Create a dedicated Protege user for Home Assistant with only the permissions it needs. The README notes that the user needs door control permission to unlock doors, so decide deliberately whether you want that at all.
- Do not automate unlock or disarm from presence sensors or voice assistants.
- Keep installer and operator credentials out of Home Assistant.
- WX or GX, firmware version, and which licences or features are enabled for integration.
- Who controls the programming (the installer, the building owner, a monitoring provider).
- A DHCP reservation and a VLAN for the controller.