Safety: this involves the keypad bus of a live alarm. Power the panel down (mains and battery) before connecting a board, or have your installer do it. If the system is monitored, tell the monitoring company first, and make sure the panel still works as a stand-alone system.
Step 0: network prep
Give the board a DHCP reservation on an IoT VLAN. Allow only Home Assistant to reach it. No port forwarding, no cloud relay.
Step 1 (option A): Envisalink EVL-4
The Envisalink integration is configured in configuration.yaml. The docs' example uses these options (check the doc for the full list):
Code: Select all
envisalink:
host: 192.168.40.20
panel_type: HONEYWELL
user_name: !secret evl_user
password: !secret evl_password
evl_version: 4
port: 4025
keepalive_interval: 60
zonedump_interval: 30
zones:
1:
name: "Back Door"
type: "opening"
2:
name: "First Floor Motion"
type: "motion"
partitions:
1:
name: "Home Alarm"Step 1 (option B): AlarmDecoder
The AlarmDecoder integration is set up in the UI: Settings > Devices & services > Add Integration > AlarmDecoder. Choose socket (host and port, for example 10000, when the board is shared over the network) or serial (path such as /dev/ttyUSB0 and a baud rate such as 115200). Then use Options to add zones. Each zone you add becomes a binary sensor. For wireless zones you can enter the RF serial number and loop so that Home Assistant can read the open and closed state and battery status.
Step 2: read-only first
Run it for a week with only monitoring. Walk each zone and confirm the binary sensor matches. Check the "ready" attribute, AC power and low battery. A simple notification is a good first automation:
Code: Select all
automation:
- alias: "Alarm panel battery low"
triggers:
- trigger: state
entity_id: alarm_control_panel.alarm_panel
attribute: battery_low
to: true
actions:
- action: notify.notify
data:
message: "Alarm panel backup battery is low"Step 3: arming
Once reads are solid, test arm away and arm stay with someone at the keypad. The AlarmDecoder docs list the key sequences it sends (for example code + 2, code + 3), and note that the "Code Required for Arming" option changes that behaviour. If the alarm has been triggered, the docs say it must be cleared (code + 1, or the disarm action) before you can arm again.
Step 4: decide what NOT to automate
- Disarming on presence or from a voice assistant.
- Bypassing zones automatically (the docs note AlarmDecoder has an auto-bypass option for Honeywell; understand what it does before using it).
- Anything that stops the panel working if Home Assistant is down.